Measuring and controlling the amount of water in oils is of considerable economic importance to the industrial community, particularly to the crude oil and electric power industries. Water content determination by Karl Fischer titration is no longer restricted to being used by a chemist in a laboratory – now the technique is used by engineers, plant operators, tanker drivers, distribution/maintenance engineers and other non-laboratory personnel.Karl Fischer titrations can now be performed in many different locations such as the tailgate of trucks, mobile laboratories, offshore installations, tankers, engineering workshops and dockside cabins. The Aquamax KF Portable is a truly mobile version of the very successful Aquamax KF Coulometer which includes Low Drift Cell twin port glassware as standard. Also incorporates a carry handle and a protective sleeve for the titration vessel and electrodes. The unique low drift cell glassware design is by far the easiest to use and also the most robust. The electrode locking system allows the joints to seal completely, without the use of grease or PTFE sleeves, and provides improved baseline stability. Hassle free assembly and disassembly. This glassware enables users to transport the instrument with reagents already in the titration cell so that it can be used immediately on arrival.
FEATURES
- Simple operation
- 10 user programmable methods
- 1 ppm/100 %
- Results in ppm, mg/kg, % water, μg water
- Multi language display & print out
- Small footprint
- Integral high speed printer
- Integral battery
- Fully portable
- Low drift cell design
- Results Manager software
- Automatically compensated errors
Technical Specifications
Titration method: | Coulometric Karl Fischer titration |
Electrolysis control: | Patented “ACE” control system Gb2370641 |
End point detection: | AC polarisation |
End point indication: | Visual display/print out/acoustic beep |
Titration vessel: | Low Drift Cell design, no grease or PTFE sleeves required |
Measuring range: | Possible 1 μg - 200 mg water Typical 1 μg - 10 mg water |
Water content: | 1 ppm - 100 % water |
Max. sensitivity: | 0.1 μg |
Max. titration speed: | 2 mg per minute |
Max. current: | 350mA |
Drift compensation: | Automatically controlled |
Precision: | 10 - 100 µg ± 3 µg; 100 µg - 1 mg ± 3 µg, above 1 mg ± 0.3 % |
Start delay time: | 0 - 30 minutes, user selectable |
End delay time | O- 30 minutes, user selectable |
Calculation modes: | Weight/weight (W/w) (user programmable), Weight/dilution ratio (W/K) Volume/density (V/SG) Volume/volume (V/v) |
Display format: | µg, mg/kg, ppm, % |
Print format: | µg, mg/kg, ppm, |
Method storage: | 10 user programmable methods |
Sample ID number: | User programmable |
Stirrer speed: | Microprocessor controlled |
Languages: | Multi languages – user selectable |
Calendar/clock: | Analysis time & date print out |
Battery low indicator: | Display & print out indication |
Data outputs | USB and RS232 ports |
Removable data storage: | Flash drive (memory stick) |
Data entry | 15 key touchpad |
Data entry | 15 key touchpad |
Display: | 40 character alphanumeric backlight LCD |
Printer: | 42 character high speed thermal printer |