miniAV®-LT Single-Bath Sub-Zero Kinematic Viscometer

miniAV®-LT Single-Bath Sub-Zero Kinematic Viscometer

CANNON miniAV-LT is a fully automated, single sample, benchtop viscometer for low temperature (sub-zero) viscosity testing. A Ubbelohde-style tube covers a viscosity range from 1–10 mm²/s (cSt) at ‒20 °C. Complies with methods ASTM D445/D446, ASTM D1655, DEF STAN 91:91, IP71, ISO 3104/3105. Common application: Jet fuel


D445 precision in a compact, robust design

  • Temperature testing at −20 °C
  • Viscosity range: 1–10 mm²/s (cSt)
  • Fits in roughly the same bench-top area as an analytical balance
  • Peltier cooling is eco-friendly and requires no pressurized coolants (an air-water heat exchanger is included)
  • A well-tested CANNON viscometer platform offers reliability and dependable support

  • Fully automated bench-top testing and reduced consumable costs

    • Affordable alternative to labor-intensive manual KV testing
    • VISCPRO® PC software enables one computer to manage and control up to four instruments
    • Automated vial washing & drying reduces vial consumption and replaces manual washing
    • ASTM D446/ISO 3105 Ubbelohde-style tube reduces solvent usage and disposal costs by 50%

    • Simplified maintenance & test versatility

      • Modular bath for easy maintenance access
      • Operators physically replace tubes in minutes, eliminating the need for service calls
      • Single-point temperature calibration avoids tube recalibration costs and maximizes test flexibility
      • Standard dual solvent input
      Technical Specifications

      UNIT WEIGHT

      Unit:: 27 kg (45 lb)
      Power Supply: 11 kg (24 lb)
      Waste Receiver:6 kg (13 lb)

      Air/Water Heat Exchanger: 14 kg (30 lb)

      METHOD ASTM D445/D446, ASTM D1655, DEF STAN 91:91, IP 71, ISO 3104/3105
      DIMENSIONS (W X D X H)

      Unit: 25.4 cm × 30.5 cm × 53.4 cm (10 in × 12 in × 21 in)
      Power Supply:: 34.3 cm × 39.6 cm × 17.2 cm (13.5 in × 15.6 in × 6.8 in)
      Waste Receiver:: 33.0 cm × 39.6 cm × 17.2 cm (13.0 in × 15.6 in × 6.8 in)
      Air/Water Heat Exchanger:: 38.6 cm × 51.1 cm × 34.9 cm (15.2 in × 20.1 in × 13.7 in)

      SHIPPING DIMENSIONS (W X D X H)

      Box 1: 73.7 cm × 63.5 cm × 94.0 cm (29 in × 25 in × 37 in)
      Box 2: 76.2 cm × 58.4 cm × 83.8 cm (30 in × 23 in × 33 in)
      Box 3: 15.2 cm × 15.2 cm × 28.0 cm (6 in × 6 in × 11 in)

      SHIPPING WEIGHT (WITH ALL ITEMS) 98.9 kg (218 lb)
      MAXIMUM THROUGHPUT 1 test per hour
      SAMPLE CAPACITY 1
      VISCOSITY RANGE 1–10 mm²/s (cSt)
      TIMING RESOLUTION 0.01 s (timing accuracy to ± 0.001 s)
      TEMPERATURE RANGE AND ACCURACY −20 °C ± 0.02 °C
      MINIMUM SAMPLE/SOLVENT VOLUME 5 mL sample/15 mL solvent per test
      OPERATING CONDITIONS 15 °C to 30 °C, 10% to 75% relative humidity (non-condensing), Installation Category II; Pollution Degree 2
      ELECTRICAL SPECIFICATIONS 100 Vac, 50/60 Hz; 115 Vac, 50/60 Hz; 230 Vac, 50/60 Hz; 1000 watts power consumption
      COMPLIANCE CE Mark; EMC directive (2004/108/EC); Low voltage directive (2006/95/EC); HI-POT (1900 Vdc, 60 sec.); ROHS
      DATA OUTPUT RS-232 via RS-485 RELATED DOCUMENTS

TOP