miniPV-H is a fully automated, single-sample, benchtop viscometer for unattended processing and testing in aggressive/corrosive solvents for dilute solution viscosity of polymers and kinematic viscosity for general purpose applications. Viscosity range for dilute solution viscosity is 0.3 mm2/s (cSt) to 700 mm2/s (cSt)* and for kinematic viscosity 0.02 mm2/s (cSt) to 1,200 mm2/s (cSt)* at 15 °C to 100 °C.
Designed to meet your viscosity testing needs
- On-board software with specialized polymer calculations determines inherent, intrinsic, kinematic, reduced, relative, and specific viscosity, as well as, molecular weight
- Integrated TE cooling provides superb temperature control from 15 °C to 100 °C
- Dilute solution polymer viscosity range: 0.3 mm²/s (cSt) to 700 mm²/s (cSt); both single range and special dual range viscometer tubes are available*
- Kinematic viscosity range: 0.02 mm²/s (cSt) to 1,200 mm²/s (cSt)*
- Fits in roughly the same benchtop area as an analytical balance to conserve valuable lab space
- Sealed system allows for measurement of atmospherically sensitive and volatile samples
- Compatible with most aggressive aqueous, aqueous, corrosive, halogenated, organic, and salt solutions
- Software controls the instrument and facilitates tasks such as calibration, data entry, method specification, calculation selection, report formatting, and data exporting
- Single PC manages up to 4 instruments using VISCPRO® software
- Reduces operator to operator variability
- Replaces manual tube cleaning with automated washing and drying
- Modular bath for easy maintenance access
- Operators physically replace tubes in minutes, eliminating the need to schedule related service calls
- Single-point temperature calibration avoids need for tube recalibration and maximizes test flexibility
- Standard dual solvent input
Compact,robust design
Fully automated benchtop testing
Simplified maintenance & test versatility
UNIT WEIGHT | Unit:: 24 kg (53 lb) |
---|---|
METHOD | ASTM D445/D446, ASTM D789, ASTM D1243, ASTM D1795, ASTM D2857, ASTM D3591, ASTM D4243, ASTM D4603, ASTM D5226, ASTM D5336, DIN 51562-1, IEC 60450, ISO 307, ISO 1628-1, ISO 1628-2, ISO 1628-4, ISO 1628-5, ISO 1628-6, ISO 3104/3105, ISO 5351, Ph. Eur. 1472, Tappi T230/PAPTAC G.24P, USP 911 |
DIMENSIONS (W X D X H) | Unit: 25.4 cm × 39.6 cm × 78.7 cm (10.0 in × 15.6 in × 30.5 in) |
SHIPPING DIMENSIONS (W X D X H) | : 73.7 cm × 63.5 cm × 94.0 cm (29.0 in × 25.0 in × 37.0 in) |
SHIPPING WEIGHT (WITH ALL ITEMS) | 117 kg (258 lb) |
MAXIMUM THROUGHPUT | Cycle time as low as 12 minutes (includes washing and drying time) |
SAMPLE CAPACITY | 1 |
VISCOSITY RANGE |
Dilute Solution: 0.3 mm2/s (cSt) to 700 mm2/s (cSt)* Kinematic: 0.02 mm2/s (cSt) to 1,200 mm2/s (cSt)* |
TIMING RESOLUTION | 0.01 s (timing accuracy to ± 0.001 s) |
TEMPERATURE RANGE AND ACCURACY | 15 °C to 100 °C, ± 0.01 °C |
MINIMUM SAMPLE/SOLVENT VOLUME | 10 mL sample/30 mL solvent for wash |
OPERATING CONDITIONS | 15 °C to 30 °C,10% to 75% relative humidity (non-condensing),Installation Category II; Pollution Degree 2 |
ELECTRICAL SPECIFICATIONS | 100 Vac,50/60 Hz; 115 Vac,50/60 Hz; 230 Vac,50/60 Hz; 1000 watts power consumption |
COMPLIANCE | CE Mark; EMC directive (2004/108/EC); Low voltage directive (2006/95/EC); HI-POT (1900 Vdc,60 sec.); ROHS |
DATA OUTPUT | RS-232 via RS-485 |