miniQV®-X SINGLE BATH KINEMATIC VISCOMETER

miniQV®-X SINGLE BATH KINEMATIC VISCOMETER

The miniQV®-X is a fully automated, single-bath, benchtop viscometer for rapid kinematic viscosity measurement of transparent and opaque liquids with ASTM D445 precision capability. A 25-position sample handler allows unattended processing. The fast-run tube covers a 10-fold viscosity range between 5 mm²/s (cSt) and 800 mm²/s (cSt) from 40 °C to 100 °C. The miniQV-X has been optimized for condition monitoring of used oils.


FEATURES AND BENEFITS

Compact, robust design

  • Temperature range: ambient to 100 °C (± 0.01 °C)
  • Kinematic viscosity range:
    • 5 mm²/s (cSt) to 800 mm²/s (cSt) in 10-fold increments at 40 °C
    • 5 mm²/s (cSt) to 50 mm²/s (cSt) in 10-fold increments at 100 °C
  • Fits in roughly the same benchtop area as an analytical balance
  • A well tested CANNON viscometer platform offers reliability and dependable support

High speed analysis

  • Analysis time: typically 3 minutes or less per test
  • 25-position removable sample handler provides unattended operation
  • Follows most ASTM D445 principles but with shorter flow times to accommodate rapid analysis

Fully automated benchtop testing

  • Affordable alternative to labor-intensive manual Kinematic Viscosity testing
  • Automates labor intensive tasks of sample measurement and viscometer tube washing and drying
  • Single PC manages up to 4 instruments using VISCPRO® software

Reduced consumable costs

  • ASTM D446/ISO 3105 fast run Ubbelohde-style tube reduces solvent usage/disposal costs
  • Low sample volume requirement of just 4 mL to 5 mL per test and solvent consumption of just 8 mL per test
  • Uses disposable, low-cost HDPE sample vials

Simplified maintenance & test versatility

  • Modular bath for easy maintenance access
  • Operators replace tubes in minutes, eliminating the need to schedule related service calls
  • Single-point temperature calibration avoids tube recalibration costs and maximizes test flexibility
  • Standard dual solvent input
Technical Specifications

UNIT WEIGHT

Unit:: 27 kg (60 lb)
Power Supply: 11 kg (24 lb)
Waste Receiver:6 kg (13 lb)

DIMENSIONS (W X D X H)

Unit: 25.4 cm × 43.7 cm × 59.8 cm (10.0 in × 17.2 in × 23.5 in)
Power Supply:: 33.0 cm × 39.6 cm × 17.2 cm (13.0 in × 15.6 in × 6.8 in)
Waste Receiver:: 33.0 cm × 39.6 cm × 17.2 cm (13.0 in × 15.6 in × 6.8 in)

SHIPPING DIMENSIONS (W X D X H)

: 73.7 cm × 63.5 cm × 94.0 cm (29.0 in × 25.0 in × 37.0 in)

SHIPPING WEIGHT (WITH ALL ITEMS) 63.5 kg (140 lb)
MAXIMUM THROUGHPUT 20 tests per hour
SAMPLE CAPACITY 25
VISCOSITY RANGE 5 mm²/s (cSt) to 800 mm²/s (cSt) in 10-fold increments at 40 °C*
5 mm²/s (cSt) to 50 mm²/s (cSt) in 10-fold increments at 100 °C
TIMING RESOLUTION 0.01 s (timing accuracy to ± 0.001 s)
TEMPERATURE RANGE AND ACCURACY 40 °C and 100 °C, ± 0.01 °C
MINIMUM SAMPLE/SOLVENT VOLUME 4 mL to 5 mL sample*/8 mL solvent per test
OPERATING CONDITIONS 15 °C to 30 °C, 10% to 75% relative humidity (non-condensing), Installation Category II; Pollution Degree 2
ELECTRICAL SPECIFICATIONS 100 Vac,50/60 Hz; 115 Vac,50/60 Hz; 230 Vac,50/60 Hz; 1000 watts power consumption
COMPLIANCE CE Mark; EMC directive (2004/108/EC); Low voltage directive (2006/95/EC); HI-POT (1900 Vdc,60 sec.); ROHS
ADDITIONAL STANDARD FEATURES Internal heated waste drain lines, dual solvent input
DATA OUTPUT RS-232 via RS-485