0OB2EIBD
Brand: World Precision Instruments
Category: Cell and tissue
Industry: Life Science and Biotechnology, Pharma, Bio-pharma & Vaccine, Clinical Research & Diagnostics, Material Science & Chemistry, Veterinary
WPI’s Micromanipulators enable sub-micron precision movement of electrodes, probes, or pipettes under a microscope, offering complete mechanical control for micro-scale applications.
Designed for stability, repeatability, and ergonomic operation, these systems are essential tools in electrophysiology, in vitro fertilization, and microinjection experiments.
Micromanipulators are critical instruments for fine mechanical placement where precision determines results. Whether positioning a micropipette for patch-clamp electrophysiology, inserting a microelectrode for extracellular recording, or performing cell-level injections, WPI’s manipulators ensure steady, reproducible movement at the micron level.
Built with rigid mechanical design, vibration damping, and smooth motion control, these manipulators provide unmatched accuracy for sensitive research environments.
Available in Manual, Manual/Motorized Hybrid, and Fully Motorized configurations, they adapt seamlessly to diverse laboratory setups.
Complementing the manipulators, WPI also provides tilt bases, piezo translators, stands, and mounting accessories, creating a complete system for precision micropositioning.
Engineered for mechanical precision and budget-conscious research, these manipulators provide smooth, stable movement with micrometer controls.
Highlights:
Fine control down to 1 µm
Robust build for long-term accuracy
Compatible with a wide range of electrodes and probes
For advanced applications demanding automated precision, these systems deliver programmable motion, remote control, and high-resolution step motors.
Highlights:
Sub-micron resolution with electronic feedback
Ideal for patch-clamp and electrophysiology work
Joystick and software interface options
Combine manual versatility with motorized precision — perfect for applications where both coarse and fine adjustments are required.
Highlights:
Dual-mode operation (manual + motorized)
Fine positioning without mechanical backlash
Ideal for multiprobe setups and dual electrode systems
Rigid and stable mounting platforms for precise positioning during experiments.
Highlights:
Magnetic bases for secure mounting
Modular arms and tilt options
Compatible with most WPI manipulators
Comprehensive range including clamps, holders, and piezo translators for enhanced control and setup flexibility.
Highlights:
Adaptable to any microscope configuration
Includes tilt bases and precision adapters
Supports multi-axis adjustments
| Model | Type | Resolution | Travel (mm) | Compatible Stands | Tilt Base | Piezo Translator | Notes |
|---|---|---|---|---|---|---|---|
| M3301 | Manual | 0.01 mm (X fine); 0.1 mm (X, Y, Z) | X(fine): 10; X: 37; Y: 20; Z: 25 | M9, M10, M10L, 501622, 501623 | TBS, M-3 | MPM20 | German precision design |
| KITE | Manual | 0.1 mm | X(fine): 10; X: 35; Y, Z: 20 | M9, M10, M10L, 501622, 501623 | TBS, M-3 | — | Made in Asia |
| M325 | Manual | 10 µm | X: 25; Y, Z: 10 | M9, M10, M10L, 501622, 501623 | TBS, M-3 | — | — |
| MMJ | Manual | 0.1 mm | X: 37; Y: 20; Z: 25 | M9, M10, M10L, 501622, 501623 | TBS, M-3 | — | Joystick control |
| MD4 | Manual | 10 µm (X fine); 100 µm (X, Y, Z) | X(fine): 10; X: 37; Y: 20; Z: 25 | M9, M10, M10L, 501622, 501623 | TBS, M-3 | — | Dual electrode configuration |
| HS6 | Manual | 5 µm | 25 mm (3 axes) | — | — | — | High-precision linear drive |
| MM3-3 | Manual (Mini) | 1.5 µm | 13 | MB-2 with MM1A adapter | — | — | 340 g load capacity |
| MM1-3 | Manual (Mini) | 1.0 µm | 3 | MB-2 | — | — | 225 g |
Enables sub-micron precision positioning
Offers vibration-free operation and mechanical stability
Compatible with electrophysiology, IVF, and neuroscience setups
Modular design allows easy integration with microscopes
Wide range of manual and motorized options for any budget or experiment
WPI Micromanipulators — Precision at the Micron Scale.
From manual systems for fundamental research to motorized manipulators for advanced electrophysiology, WPI provides complete micropositioning solutions that deliver accuracy, reliability, and effortless control — every time.
| Specification | Description |
|---|---|
| Positioning Resolution | 1 µm to 100 µm (model dependent) |
| Axis Configuration | 3-axis (X, Y, Z) precision control |
| Drive Mechanism | Micrometer screw or stepper motor |
| Travel Range | Up to 37 mm (coarse), 10 mm (fine) |
| Load Capacity | 200–340 g (manual models) |
| Construction | High-stability metal alloy with damping mounts |
| Optional Add-ons | Piezo translator, tilt base, magnetic stand |
| Control Interface (Motorized) | Joystick or PC software |
| Applications | Microinjection, patch-clamp, IVF, cell manipulation |
| Field | Application |
|---|---|
| Neuroscience | Intracellular and extracellular recording |
| Electrophysiology | Patch clamp and ion channel studies |
| Cell Biology | Microinjection, IVF, cell manipulation |
| Biomedical Engineering | Nanoprobe placement and precision assembly |
| Material Science | Micro-positioning for structural studies |
Product added to quotation. It will not be sent until you hit Submit!
The will be emailed to you shortly.
Sending download link to your email...
Please waitInsights That Matter
Select which types of cookies you want to allow. Essential cookies are always enabled.
These are necessary for the website to function and cannot be disabled.
Remember your preferences (e.g. language, region).
Help us understand how visitors interact with the site (e.g. Google Analytics).
Used for personalized offers and advertising.
Your Request is being submit.