VOW8DR38
Brand: Restek
Category: GC Accessories
Industry: Academia, Clinical Research & Diagnostics, Petroleum & Petrochemicals, Food, Agricultural & Environmental, Life Science and Biotechnology, Semiconductors, Pharma, Bio-pharma & Vaccine
As authorized Restek dealers, we provide a comprehensive range of GC accessories and consumables designed to support reliable gas chromatography performance. Our offering includes inlet liners and liner supplies, septa, ferrules, inlet accessories, column connectors, detector supplies, autosampler replacement parts, syringes, vials and well plates, along with maintenance supplies and tools for capillary columns, ensuring consistent results, efficient operation, and extended instrument life.
Labindia Instruments is the official dealer for Restek in India, offering a complete range of Restek Gas Chromatography products to support accurate and reliable GC performance. We supply high-quality GC accessories and consumables designed to maintain system efficiency, improve reproducibility, and extend instrument life.
Our portfolio includes Restek Inlet Liners, Restek Liner Supplies, Restek Septa, and Restek Ferrules, along with inlet accessories, column connectors, detector supplies, autosampler replacement parts, syringes, vials, well plates, and essential maintenance tools for capillary columns. Each product is engineered to deliver consistent results, reduce downtime, and ensure smooth laboratory operations.
Whether you require routine replacement parts or complete GC consumable solutions, we provide competitive pricing, technical support, and dependable service across India. With Labindia Instruments as your trusted Restek partner, you gain access to high-performance chromatography products that help maintain precision, efficiency, and long-term instrument reliability.
-Sample is contained in the needle with full plunger displacement, ensuring no dead volume. -High precision and accuracy down to 0.1 µL. -Seal between the plunger and the needle can be tightened for high-pressure injection. -Replaceable needle/plunger kits and barrels (available on request).
Unlike other designs, Alta-Robbins rupture disk tee is NOT permanently soldered to the disk, making the disks replaceable. Disks are easily changed without removing the valve or tee from the cylinder. These tees are designed to be installed into existing systems to provide reliable overpressure protection.
-Protect contents and prevent carryover with preslit cap mats. -Chemically resistant, silicone mats are excellent for compound storage to -80 °C. -Preslit mats pierceable by autosampler needle, pipette tip, or probe. -Mat for sealing 0.45, 1.3, and 2.0 mL plates. -Designed for Nunc round, shared-well 96-well plates. -Built to ANSI standards. -Compatible with 96-well plates meeting ANSI standards.
Preconditioned to eliminate outgassing. High-purity, high-density graphite. Smoother surface and cleaner edges than conventional graphite ferrules. Contain no binders that can off-gas or adsorb analytes. Stable to 450 °C.
Routine Maintenance with FastPack Inlet Kits (1 pack includes 5 maintenance kits.) What are the benefits of using a FastPack Inlet Kit? Injection port maintenance should be performed prior to installing any capillary column and on a routine basis, based on the number of injections made and the cleanliness of the samples.
-Does not require a separate washer. -Requires less torque to seal. -Does not require retightening of reducing nut after several oven cycles. -Extends column lifetime by preventing oxygen from reaching the column. -Same price as the regular inlet seals with washers. -Available in stainless steel, gold-plated, or Siltek-treated. Gold plating or Siltek treatment provide enhanced inertness versus stainless steel.
Set comes with screwdrivers, pliers, wrenches, sockets, scissors, clamps, and more. Durable, zippered, notebook-style carrying case for easy transport.
- 40% larger opening than other vials.
- Step profile automatically centers glass flange limited volume inserts.
- Preassembled caps with septa, with or without vials.
- Designed for Waters Alliance autosamplers.
-Proprietary specialized surface material resulting in very high secondary electron emission. -Air stable. -Two-year shelf life guarantee. -Discrete dynode design results in extended operating life. Optimized ion and electronic optics for maximum performance. Increased surface area for enhanced sensitivity and extended operational life.
Choose preslit caps (available for some vials) to reduce the risk of needle bending, release vacuum from high-volume injections, and improve injection reproducibility when greater than 20% of vial volume is withdrawn.
⦁ Reliably create permanent connections between fused silica analytical columns, guard columns, and retention gaps.
⦁ SilTite FingerTite technology provides easy installation and a permanent leak-tight connection.
⦁ Deactivated metal and zero-dead-volume design ensure optimal peak shapes.
Product added to quotation. It will not be sent until you hit Submit!
The will be emailed to you shortly.
Sending download link to your email...
Please waitInsights That Matter
Select which types of cookies you want to allow. Essential cookies are always enabled.
These are necessary for the website to function and cannot be disabled.
Remember your preferences (e.g. language, region).
Help us understand how visitors interact with the site (e.g. Google Analytics).
Used for personalized offers and advertising.
Your Request is being submit.